Inspection 344304126 OPENED SEP 6, 2019Closed
Eastheaven Eastates, Wentzville, MO 63385 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hawk Point, Missouri · Water and Sewer Line and Related Structures Construction · NAICS 237110
Since 2019, OSHA inspectors have visited Arc Grading, LLC in Missouri 3 times.
The most recent inspection opened on Sep 6, 2019 as a planned inspection, in Wentzville.
In all, OSHA issued 4 citation items: 4 serious.
The proposed penalties came to $8,808; today they stand at $7,359, 16% less.
The rule cited most here is 1926.651 (excavations), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Arc Grading, LLC averages $3,680 across 2 cited inspections.
Want to know if OSHA cites Arc Grading, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this companyEastheaven Eastates, Wentzville, MO 63385 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Near 844 Franklin Street, Hawk Point, MO 63349 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $3,978 | $3,978 | Aug 13, 2019 | Final |
Highway A & Joseph Street Across The Street From The Veterans Of Foreign Wars, Hawk Point, MO 63349 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Serious | $2,415 | $1,690 | Feb 21, 2019 | Final |
| Citation 1, item 2a 29 CFR 1926.651(j)(1) · Excavations |
Serious | $2,415 | $1,690 | Feb 21, 2019 | Final |
| Citation 1, item 2b 29 CFR 1926.651(j)(2) · Excavations |
Serious | $0 | $0 | Feb 21, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.651(c)(2)
(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.
29 CFR 1926.651(j)(1)
(j) Protection of employees from loose rock or soil. (1) Adequate protection shall be provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face. Such protection shall consist of scaling to remove loose material; installation of protective barricades at intervals as necessary on the face to stop and contain falling material; or other means that provide equivalent protection.
29 CFR 1926.651(j)(2)
(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.