OSHA SearchOSHA records by employer

Architectural Metals LLC: OSHA inspections and violations

Madison, Wisconsin · Other Building Finishing Contractors · NAICS 238390

8inspections
12citation items
$17,665current penalties
Sep 19, 2018last inspection

OSHA has inspected Architectural Metals LLC 8 times in Wisconsin since 1986.

The latest one began on Sep 19, 2018 as a planned inspection, in Oregon.

Those inspections ended with 12 citation items: 11 serious and 1 repeat.

Penalties were first proposed at $40,819 and now stand at $17,665, 57% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 5 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Architectural Metals LLC averages $8,315 (1 cited inspection).

Architectural Metals LLC: OSHA citation items per year, 1986 to 2018
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Architectural Metals LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343472858 OPENED SEP 19, 2018Closed

Planned · Partial · Safety · 19 employees at the site · Closed Oct 16, 2018

900 Oregon Center Drive, Oregon, WI 53575 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$6,467$2,772Sep 26, 2018Final
Citation 1, item 1b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$6,467$0Sep 26, 2018Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$12,935$5,543Sep 26, 2018Final

Inspection 339807133 OPENED JUN 12, 2014Closed

Planned · Partial · Safety · 40 employees at the site · Closed Sep 18, 2014

6602 Dominion Drive, Madison, WI 53718 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,850$2,250Jun 25, 2014Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,850$2,250Jun 25, 2014Final

Inspection 313522815 OPENED AUG 19, 2009Closed

Planned · Partial · Safety · 15 employees at the site · Closed Dec 7, 2009

501 W. Rawson Ave., Oak Creek, WI 53154 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$750$450Oct 23, 2009Closed
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$900Oct 23, 2009Closed

Inspection 310770433 OPENED MAR 30, 2009Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jun 16, 2009

1001 Nygaard Street, Stoughton, WI 53589 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$1,050May 29, 2009Closed
Citation 1, item 1b
29 CFR 1926.502(h)(1)(v) · Fall protection systems
Serious$0$0May 29, 2009Closed
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$750$525May 29, 2009Closed

Inspection 306794959 OPENED FEB 25, 2004Closed

Planned · Partial · Safety · 23 employees at the site · Closed Mar 15, 2004

805 Creske Ave, Mosinee, WI 54455 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,500$1,050Mar 9, 2004Closed

Inspection 303894687 OPENED DEC 11, 2002Closed

Planned · Partial · Safety · 18 employees at the site · Closed Jan 13, 2003

888 Watson Avenue, Madison, WI 53713 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,250$875Dec 18, 2002Closed

Inspection 300568177 OPENED MAY 26, 1999Closed

Planned · No inspection · Safety · 25 employees at the site · Closed Jun 8, 1999

888 Watson Avenue, Madison, WI 53713 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1322858 OPENED MAR 5, 1986Closed

Planned · Complete · Safety · 1 employee at the site · Closed Mar 5, 1986

7825 Big Sky Dr., Madison, WI 53719 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other other building finishing contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.