OSHA SearchOSHA records by employer

Archway Inc.: OSHA inspections and violations

Tamuning, Guam · General Warehousing and Storage · NAICS 493110

3inspections
14citation items
$21,484current penalties
Oct 21, 2024last inspection

Since 2021, OSHA inspectors have visited Archway Inc. in Guam 3 times.

The most recent inspection opened on Oct 21, 2024 as a planned inspection, in Tamuning.

In all, OSHA issued 14 citation items: 4 serious, 3 repeat and 7 other-than-serious.

The proposed penalties came to $30,336; today they stand at $21,484, 29% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among transportation and warehousing employers, the typical cited inspection since 2015 ends with a $3,560 penalty. Archway Inc. averages $7,161 across 3 cited inspections.

Archway Inc.: OSHA citation items per year, 2021 to 2024
Citation items per year, by inspection date.

Guam · latest 90 days of OSHA records

6employers cited

Get notified the morning OSHA posts each new citation in Guam: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Guam

Checking a subcontractor, a client or your own company? Watch Archway Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347842569 OPENED OCT 21, 2024Closed

Planned · Complete · Safety · 40 employees at the site · Closed Mar 17, 2025

147 Serenu Ave., Tamuning, GU 96931 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Repeat$414$414Dec 11, 2024Final
Citation 1, item 1b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Repeat$0$0Dec 11, 2024Final
Citation 1, item 3
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Repeat$414$414Dec 11, 2024Final
Citation 2, item 1
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 11, 2024Final

Inspection 346305360 OPENED OCT 25, 2022Closed

Planned · Complete · Safety · 40 employees at the site · Closed Sep 11, 2023

147 Serenu Ave., Tamuning, GU 96931 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(b)(1) · Exit route design
Serious$5,594$3,916Nov 8, 2022Final
Citation 1, item 2
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$9,324$6,527Nov 8, 2022Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$9,324$6,527Nov 8, 2022Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 8, 2022Final
Citation 2, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Nov 8, 2022Final
Citation 2, item 3
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Nov 8, 2022Final
Citation 2, item 4
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Nov 8, 2022Final

Inspection 345509517 OPENED SEP 2, 2021Closed

Planned · Complete · Safety · 50 employees at the site · Closed Jan 4, 2022

147 Serenu Ave., Tamuning, GU 96931 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$5,266$3,686Nov 17, 2021Final
Citation 2, item 1
29 CFR 1910.29(b)(1) · Fall protection systems in general industry
Other-than-serious$0$0Nov 17, 2021Final
Citation 2, item 2
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$0$0Nov 17, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other general warehousing and storage employers in Guam

Alert subscribers get notified of each newly cited employer in Guam the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.