OSHA SearchOSHA records by employer

Arcoiris Masonry Inc: OSHA inspections and violations

Orlando, Florida · Masonry Contractors · NAICS 238140

1inspections
2citation items
$3,672current penalties
Jun 15, 2023last inspection

OSHA inspectors have visited Arcoiris Masonry Inc in Florida one time.

It opened on Jun 15, 2023 on a referral, in Orlando.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $6,698; today they stand at $3,672, 45% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Arcoiris Masonry Inc averages $3,672 across 1 cited inspection.

Arcoiris Masonry Inc: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Arcoiris Masonry Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346775455 OPENED JUN 15, 2023Closed

Referral · Partial · Safety · 5 employees at the site · Closed Mar 24, 2024

13985 Landstar Blvd, Orlando, FL 32824 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,349$1,836Oct 23, 2023Final
Citation 1, item 2
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Serious$3,349$1,836Oct 23, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(3)

(3) Frames and panels shall be joined together vertically by coupling or stacking pins or equivalent means.

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.