OSHA SearchOSHA records by employer

Areva Inc: OSHA inspections and violations

Braceville, Illinois · Engineering Services · NAICS 541330

2inspections
3citation items
$18,108current penalties
Mar 17, 2017last inspection

OSHA has inspected Areva Inc 2 times in Illinois since 2016.

The latest one began on Mar 17, 2017 to monitor an earlier case, in Byron.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $27,162 and now stand at $18,108, 33% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 3 items under 1910.147.

How that compares: the median penalty per cited inspection for professional services employers since 2015 is $1,821, and Areva Inc averages $18,108 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Areva Inc: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Areva Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342185949 OPENED MAR 17, 2017Closed

Monitoring · Partial · Safety · 5,000 employees at the site · Closed Mar 20, 2017

Excelon - Byron Nuclear Generating Station, Byron, IL 61010 · Nuclear Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341855658 OPENED OCT 21, 2016Closed

Referral · Partial · Safety · 5,000 employees at the site · Closed Apr 17, 2017

35100 Illinois 53, Braceville, IL 60407 · Engineering Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$9,054$9,054Feb 22, 2017Final
Citation 1, item 2a
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$9,054$9,054Feb 22, 2017Final
Citation 1, item 2b
29 CFR 1910.147(d) · Lockout/tagout
Serious$9,054$0Feb 22, 2017Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 17, 2016, Braceville: Amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was rebuilding an intensifier on a high-pressure pump when the machine became energized by a remote operator. The piston on the pump extended on a hydraulic cylinder while the employee's hands were in the machine, pinching and amputating a finger between the cylinder and machine.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(5)(i)

(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.

29 CFR 1910.147(d)

(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:

Other engineering services employers in Illinois