OSHA SearchOSHA records by employer

Arg Construction LLC: OSHA inspections and violations

Hartland, Wisconsin · Roofing Contractors · NAICS 238160

1inspections
4citation items
$2,700current penalties
Jun 5, 2019last inspection

OSHA has inspected Arg Construction LLC once in Wisconsin.

The inspection began on Jun 5, 2019 as a planned inspection, in Hartland.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $6,819 and now stand at $2,700, 60% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Arg Construction LLC averages $2,700 (1 cited inspection).

Arg Construction LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Arg Construction LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344058862 OPENED JUN 5, 2019Closed

Planned · Partial · Safety · 9 employees at the site · Closed Jul 29, 2019

1219 Sweetbriar Lane, Hartland, WI 53029 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,273$1,600Jun 14, 2019Final
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,273$0Jun 14, 2019Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,273$1,100Jun 14, 2019Final
Citation 2, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Jun 14, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Wisconsin

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.