OSHA SearchOSHA records by employer

Arm Electric LLC: OSHA inspections and violations

Houston, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
3citation items
$6,810current penalties
Jul 15, 2025last inspection

OSHA has inspected Arm Electric LLC once in Texas.

The inspection began on Jul 15, 2025 after a fatality or catastrophe, in Houston; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $6,810 and still stand at $6,810.

Working near live electrical parts comes up most often in these citations: 3 items under 1910.333.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Arm Electric LLC averages $6,810 (1 cited inspection).

Arm Electric LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Arm Electric LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348369570 OPENED JUL 15, 2025Open

Fatality or catastrophe · Partial · Safety · 3 employees at the site · Open

11246 S. Wilcrest Drive Savoy Restaurant, Houston, TX 77099 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$3,972$3,972Jan 5, 2026Final
Citation 1, item 1b
29 CFR 1910.333(b)(2)(ii)(b) · Working near live electrical parts
Serious$0$0Jan 5, 2026Final
Citation 1, item 2
29 CFR 1910.333(c)(5) · Working near live electrical parts
Serious$2,838$2,838Jan 5, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1910.333(b)(2)(ii)(b)

(B) The circuits and equipment to be worked on shall be disconnected from all electric energy sources. Control circuit devices, such as push buttons, selector switches, and interlocks, may not be used as the sole means for deenergizing circuits or equipment. Interlocks for electric equipment may not be used as a substitute for lockout and tagging procedures.

29 CFR 1910.333(c)(5)

(5) Confined or enclosed work spaces. When an employee works in a confined or enclosed space (such as a manhole or vault) that contains exposed energized parts, the employer shall provide, and the employee shall use, protective shields, protective barriers, or insulating materials as necessary to avoid inadvertent contact with these parts. Doors, hinged panels, and the like shall be secured to prevent their swinging into an employee and causing the employee to contact exposed energized parts.

Other electrical contractors and other wiring installation contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.