OSHA SearchOSHA records by employer

Arnold Electric Company, Inc.: OSHA inspections and violations

North Little Rock, Arkansas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
5citation items
$30,351current penalties
Mar 11, 2026last inspection

OSHA has inspected Arnold Electric Company, Inc. 2 times in Arkansas since 2024.

The latest one began on Mar 11, 2026 after a fatality or catastrophe, in Pine Bluff; the case is still open.

Those inspections ended with 5 citation items: 5 serious.

Penalties were first proposed at $53,504 and now stand at $30,351, 43% lower after settlements or reviews.

Electrical safety in construction comes up most often in these citations: 2 items under 1926.416.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Arnold Electric Company, Inc. averages $15,175 (2 cited inspections).

Arnold Electric Company, Inc.: OSHA citation items per year, 2024 to 2026
Citation items per year, by inspection date.

Arkansas · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Arkansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arkansas

Checking a subcontractor, a client or your own company? Watch Arnold Electric Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348800202 OPENED MAR 11, 2026Open

Fatality or catastrophe · Partial · Safety · 22 employees at the site · Open

711 W 11th Ave, Pine Bluff, AR 71601 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 4
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$8,511$8,511Sep 10, 2026Final
Citation 5, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$14,895$16,550Sep 10, 2026Final
Citation 5, item 1b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$10,641$0Sep 10, 2026Final
Citation 5, item 1c
29 CFR 1926.417(a) · Lockout and tagging of circuits
Serious$10,641$0Sep 10, 2026Final

Inspection 347327983 OPENED MAR 6, 2024Closed

Planned · Complete · Safety · 29 employees at the site · Closed Jul 23, 2024

14001 Us 70, North Little Rock, AR 72117 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$8,816$5,290Jul 1, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.417 · Lockout and tagging of circuits

Other electrical contractors and other wiring installation contractors employers in Arkansas

Alert subscribers get notified of each newly cited employer in Arkansas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.