OSHA SearchOSHA records by employer

Artchitectural.Com 2 LLC: OSHA inspections and violations

San Antonio, Texas · Custom Architectural Woodwork and Millwork Manufacturing · NAICS 337212

1inspections
10citation items
$1,500current penalties
Aug 9, 2016last inspection

OSHA inspectors have visited Artchitectural.Com 2 LLC in Texas one time.

It opened on Aug 9, 2016 as a planned inspection, in San Antonio.

In all, OSHA issued 10 citation items: 10 serious.

The proposed penalties came to $17,637; today they stand at $1,500, 91% less.

The rule cited most here is 1910.213 (woodworking machinery), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Artchitectural.Com 2 LLC averages $1,500 across 1 cited inspection.

Artchitectural.Com 2 LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Artchitectural.Com 2 LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341683563 OPENED AUG 9, 2016Closed

Planned · Partial · Health · 6 employees at the site · Closed Sep 25, 2017

1350 E. Southcross, San Antonio, TX 78223 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$2,138$214Oct 11, 2016Final
Citation 1, item 2
29 CFR 1910.212(b) · Machine guarding
Serious$2,138$214Oct 11, 2016Final
Citation 1, item 3a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$3,741$214Oct 11, 2016Final
Citation 1, item 3b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Oct 11, 2016Final
Citation 1, item 3c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Oct 11, 2016Final
Citation 1, item 4
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$2,672$214Oct 11, 2016Final
Citation 1, item 5
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$2,138$214Oct 11, 2016Final
Citation 1, item 6
29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements
Serious$2,138$214Oct 11, 2016Final
Citation 1, item 7a
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$2,672$214Oct 11, 2016Final
Citation 1, item 7b
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Oct 11, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(b)

(b) Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other custom architectural woodwork and millwork manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.