OSHA SearchOSHA records by employer

Ascend Elements: OSHA inspections and violations

Novi, Michigan · Primary Battery Manufacturing · NAICS 335912

1inspections
2citation items
$200current penalties
Nov 6, 2023last inspection

OSHA has inspected Ascend Elements once in Michigan.

The inspection began on Nov 6, 2023 after a complaint, in Novi.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $400 and now stand at $200, 50% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 2 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Ascend Elements averages $200 (1 cited inspection).

Ascend Elements also files yearly injury logs with OSHA, summarized below.

Ascend Elements: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Ascend Elements again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347083800 OPENED NOV 6, 2023Closed

Complaint · Partial · Health · 10 employees at the site · Closed Apr 22, 2024

27101 Cabaret Dr, Novi, MI 48377 · Primary Battery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(g)(1)(i) · Respiratory protection
Serious$400$200Mar 21, 2024Final
Citation 1, item 1b
29 CFR 1910.134(h)(2) · Respiratory protection
Serious$0$0Mar 21, 2024Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Novi site logged 0 recordable injuries or illnesses among about 27 workers: 0.0 per 100 full-time workers, against a median of 1.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Ascend Elements - Cathode Production and Development
Novi · 2024
27 000.01.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(g)(1)(i)

(1) Facepiece seal protection. (i) The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have:

29 CFR 1910.134(h)(2)

(2) Storage. The employer shall ensure that respirators are stored as follows:

Other primary battery manufacturing employers in Michigan

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.