OSHA SearchOSHA records by employer

Aspen Plumbing, LLC: OSHA inspections and violations

Omaha, Nebraska · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
5citation items
$11,200current penalties
Mar 2, 2015last inspection

OSHA inspectors have visited Aspen Plumbing, LLC in Nebraska one time.

It opened on Mar 2, 2015 after a complaint, in Omaha.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $11,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.651 (excavations), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Aspen Plumbing, LLC averages $11,200 across 1 cited inspection.

Aspen Plumbing, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Nebraska · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in Nebraska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nebraska

Checking a subcontractor, a client or your own company? Watch Aspen Plumbing, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340436195 OPENED MAR 2, 2015Closed

Complaint · Complete · Safety · 5 employees at the site · Closed Oct 9, 2015

3454 Ames Avenue, Omaha, NE 68111 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,800$2,800Jun 25, 2015Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$2,800$2,800Jun 25, 2015Final
Citation 1, item 3a
29 CFR 1926.651(k)(1) · Excavations
Serious$2,800$2,800Jun 25, 2015Final
Citation 1, item 3b
29 CFR 1926.651(k)(2) · Excavations
Serious$0$0Jun 25, 2015Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,800$2,800Jun 25, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection