Inspection 345164818 OPENED FEB 25, 2021Closed
3000 Highway 74 East, Monroe, NC 28112 · Hardware Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Monroe, North Carolina · Hardware Manufacturing · NAICS 332510
Assa Abloy Accessories and Door Controls Group, I has 2 OSHA inspections on record in North Carolina, the first in 2020.
OSHA's last visit started on Feb 25, 2021 to follow up on an earlier case, in Monroe.
Across those inspections OSHA issued 3 citation items: 3 serious.
OSHA proposed $19,600 in penalties. After settlements and reviews the total is $13,300, down 32%.
Most often, OSHA cited 1910.147, lockout/tagout (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Assa Abloy Accessories and Door Controls Group, I averages $13,300 over 1 cited inspection in that time.
North Carolina · latest 90 days of OSHA records
228employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Assa Abloy Accessories and Door Controls Group, I and get notified the morning OSHA posts a new citation for it.
Watch this company3000 Highway 74 East, Monroe, NC 28112 · Hardware Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3000 Highway 74 East, Monroe, NC 28112 · Hardware Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $7,000 | $7,000 | Jul 21, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $6,300 | $3,150 | Jul 21, 2020 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout |
Serious | $6,300 | $3,150 | Jul 21, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
29 CFR 1910.147(c)(7)(i)(a)
(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.