OSHA SearchOSHA records by employer

Athens Utilities Board-Gas Department: OSHA inspections and violations

Athens, Tennessee · Natural Gas Distribution · NAICS 221210

1inspections
3citation items
$0current penalties
Aug 18, 2017last inspection

Athens Utilities Board-Gas Department has one OSHA inspection on record in Tennessee.

OSHA opened it on Aug 18, 2017 as a planned inspection, in Athens.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA did not attach a penalty to any of these citations.

For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Athens Utilities Board-Gas Department averages $0 over 1 cited inspection in that time.

Athens Utilities Board-Gas Department: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

335employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Athens Utilities Board-Gas Department and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342581584 OPENED AUG 18, 2017Closed

Planned · Complete · Safety · Local government · 2 employees at the site · Closed Oct 5, 2017

220 Alford Street, Athens, TN 37303 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$0$0Sep 5, 2017Final
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Sep 5, 2017Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Sep 5, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.243(c)(3)

(3) Vertical portable grinders. Safety guards used on machines known as right angle head or vertical portable grinders shall have a maximum exposure angle of 180°, and the guard shall be so located so as to be between the operator and the wheel during use. Adjustment of guard shall be such that pieces of an accidentally broken wheel will be deflected away from the operator. (See Figure P-4.)

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.