Inspection 348443243 OPENED AUG 15, 2025Closed
1181 Cassville White Rd Ne, White, GA 30184 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2016, OSHA inspectors have visited Atkore International, Inc. in Georgia 4 times.
The most recent inspection opened on Aug 15, 2025 to monitor an earlier case, in White.
In all, OSHA issued 3 citation items: 1 serious and 2 other-than-serious.
The proposed penalties came to $33,997; today they stand at $28,372, 17% less.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Atkore International, Inc. averages $9,457 across 3 cited inspections.
Atkore International, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Georgia · latest 90 days of OSHA records
148employers cited
Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Georgia
Checking a subcontractor, a client or your own company? Watch Atkore International, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Atkore International, Inc. at 7 sites in 5 states. Together they've had 13 inspections and $88,178 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 7 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans1181 Cassville White Rd Ne, White, GA 30184 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
560 Wharton Circle Sw., Atlanta, GA 30336 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $16,131 | $16,131 | Apr 15, 2024 | Final |
560 Wharton Circle Sw, Atlanta, GA 30336 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.157(d)(6) · Portable fire extinguishers |
Serious | $14,063 | $8,438 | Jul 14, 2023 | Final |
1206 Sunset Dr, Thomasville, GA 31792 · Plastics Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.242(a) · Hand and power tools |
Other-than-serious | $3,803 | $3,803 | May 23, 2017 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Atlanta site logged 3 recordable injuries or illnesses among about 87 workers: 3.7 per 100 full-time workers, against a median of 2.4 for its industry. Those cases cost 50 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Atkore - Atlanta Atlanta · 2023 | 87 | 3 | 3 | 3.7 | 2.4 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Dec 22, 2023, Atlanta: Amputation · amputations · fingertip(s)
An employee was guiding aluminum material through a roller machine when their left hand contacted the moving parts. The employee's left index fingertip was amputated.
Jan 10, 2023, Atlanta: Hospitalization · symptoms involving cardiovascular system, unspecified · heart
An employee was using a fire extinguisher to fight an incipient fire when they suffered smoke inhalation, triggering heart rhythm irregularities.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.157(d)(6)
(6) The employer shall distribute portable fire extinguishers or other containers of Class D extinguishing agent for use by employees so that the travel distance from the combustible metal working area to any extinguishing agent is 75 feet (22.9 m) or less. Portable fire extinguishers for Class D hazards are required in those combustible metal working areas where combustible metal powders, flakes, shavings, or similarly sized products are generated at least once every two weeks.
29 CFR 1910.212(a)(1)
(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.
29 CFR 1910.242(a)
(a) General requirements. Each employer shall be responsible for the safe condition of tools and equipment used by employees, including tools and equipment which may be furnished by employees.
Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.