OSHA SearchOSHA records by employer

Atlantis Pools LLC: OSHA inspections and violations

Virginia Beach, Virginia · All Other Specialty Trade Contractors · NAICS 238990

1inspections
6citation items
$2,268current penalties
Apr 5, 2019last inspection

OSHA has inspected Atlantis Pools LLC once in Virginia.

The inspection began on Apr 5, 2019 as a planned inspection, in Virginia Beach.

That inspection ended with 6 citation items: 4 serious and 2 other-than-serious.

Penalties were first proposed at $3,240 and now stand at $2,268, 30% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Atlantis Pools LLC averages $2,268 (1 cited inspection).

Atlantis Pools LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Atlantis Pools LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343909446 OPENED APR 5, 2019Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jun 28, 2019

2800 Pacific Ave., Virginia Beach, VA 23451 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,620$1,134May 31, 2019Final
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0May 31, 2019Final
Citation 1, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,620$1,134May 31, 2019Final
Citation 1, item 2b
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$0$0May 31, 2019Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0May 31, 2019Final
Citation 2, item 2
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0May 31, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other all other specialty trade contractors employers in Virginia