Auburn CSD Warehouse & Receiving: OSHA inspections and violations

Auburn, New York · Elementary and Secondary Schools · NAICS 611110

4inspections
7citation items
$0current penalties
Jul 22, 2015last inspection

Auburn CSD Warehouse & Receiving has 4 OSHA inspections on record in New York, the first in 2011.

OSHA's last visit started on Jul 22, 2015 to follow up on an earlier case, in Auburn.

Across those inspections OSHA issued 7 citation items: 6 serious and 1 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all education employers the median penalty per cited inspection since 2015 is $0. Auburn CSD Warehouse & Receiving averages $0 over 1 cited inspection in that time.

Auburn CSD Warehouse & Receiving: OSHA citation items per year, 2011 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

361employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Auburn CSD Warehouse & Receiving and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340798966 OPENED JUL 22, 2015Closed

Follow-up · Partial · Safety · Local government · 47 employees at the site · Closed Jul 22, 2015

78 Thornton Ave, Auburn, NY 13021 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340645563 OPENED MAY 20, 2015Closed

Planned · Complete · Safety · Local government · 47 employees at the site · Closed Jul 22, 2015

78 Thornton Ave, Auburn, NY 13021 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(b)(1)(i) · Guarding floor and wall openings and holes
Serious$0$0Jun 17, 2015Final
Citation 1, item 2
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Serious$0$0Jun 17, 2015Final
Citation 1, item 3
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Jun 17, 2015Final
Citation 2, item 1
29 CFR 1910.37(a)(4) · Exit routes
Other-than-serious$0$0Jun 17, 2015Final

Inspection 315326033 OPENED AUG 25, 2011Closed

Follow-up · Partial · Safety · Local government · 47 employees at the site · Closed Aug 25, 2011

78 Thornton Ave, Auburn, NY 13021 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313568040 OPENED JUN 23, 2011Closed

Planned · Complete · Safety · Local government · 47 employees at the site · Closed Aug 24, 2011

78 Thornton Ave, Auburn, NY 13021 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Jul 8, 2011Closed
Citation 1, item 2
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Serious$0$0Jul 8, 2011Closed
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Jul 8, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(g)(1)(iii)

(iii) At least one entrance of sufficient area shall be provided to give access to the working space about electric equipment.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.37 · Exit routes

Other elementary and secondary schools employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.