Aviator Brewing Company, Inc.: OSHA inspections and violations

Fuquay Varina, North Carolina · Breweries · NAICS 312120

2inspections
4citation items
$2,000current penalties
Jan 24, 2019last inspection

OSHA has inspected Aviator Brewing Company, Inc. 2 times in North Carolina since 2013.

The latest one began on Jan 24, 2019 after a complaint, in Fuquay Varina.

Those inspections ended with 4 citation items: 2 serious and 2 other-than-serious.

Penalties were first proposed at $2,000 and still stand at $2,000.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,870, and Aviator Brewing Company, Inc. averages $1,500 (1 cited inspection).

Aviator Brewing Company, Inc.: OSHA citation items per year, 2013 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Aviator Brewing Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343735148 OPENED JAN 24, 2019Closed

Complaint · Partial · Health · 5 employees at the site · Closed Aug 25, 2021

601 East Broad Street, Fuquay Varina, NC 27526 · Food Services and Drinking Places · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1101(k)(2)(i) · Asbestos in construction
Serious$1,500$1,500Mar 26, 2019Final

Inspection 316782911 OPENED MAR 5, 2013Closed

Planned · Complete · Safety · 9 employees at the site · Closed Apr 23, 2013

209 Technology Park Lane, Fuquay Varina, NC 27526 · Breweries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$500$500Mar 11, 2013Closed
Citation 2, item 1
29 CFR 1910.157(e)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 11, 2013Closed
Citation 2, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 11, 2013Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(1)

(e) Inspection, maintenance and testing. (1) The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(ii)

(ii) Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(ii)

(ii) If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made.

29 CFR 1926.1101 · Asbestos in construction