OSHA SearchOSHA records by employer

Awc Frac Valves: OSHA inspections and violations

Lore City, Ohio · Support Activities for Oil and Gas Operations · NAICS 213112

1inspections
3citation items
$8,250current penalties
Aug 10, 2015last inspection

Awc Frac Valves has one OSHA inspection on record in Ohio.

OSHA opened it on Aug 10, 2015 after a complaint, in Lore City.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $9,900 in penalties. After settlements and reviews the total is $8,250, down 17%.

For context, across all mining and oil and gas employers the median penalty per cited inspection since 2015 is $2,883. Awc Frac Valves averages $8,250 over 1 cited inspection in that time.

Awc Frac Valves: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Awc Frac Valves and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340841667 OPENED AUG 10, 2015Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Dec 23, 2015

64201 Wintergreen Road, Lore City, OH 43755 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$4,400$4,400Nov 19, 2015Final
Citation 1, item 2
29 CFR 1910.334(b)(2) · Using electrical equipment
Serious$5,500$3,850Nov 19, 2015Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 19, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(b)(2)

(2) Reclosing circuits after protective device operation. After a circuit is deenergized by a circuit protective device, the circuit may not be manually reenergized until it has been determined that the equipment and circuit can be safely energized. The repetitive manual reclosing of circuit breakers or reenergizing circuits through replaced fuses is prohibited.