OSHA SearchOSHA records by employer

Axel Royal, LLC: OSHA inspections and violations

Schertz, Texas · Petroleum Lubricating Oil and Grease Manufacturing · NAICS 324191

1inspections
5citation items
$18,738current penalties
Jan 28, 2020last inspection

OSHA has inspected Axel Royal, LLC once in Texas.

The inspection began on Jan 28, 2020 on a referral, in Schertz.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $31,230 and now stand at $18,738, 40% lower after settlements or reviews.

Safeguards for personnel protection comes up most often in these citations: 2 items under 1910.335.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Axel Royal, LLC averages $18,738 (1 cited inspection).

Axel Royal, LLC also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Axel Royal, LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Axel Royal, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344586912 OPENED JAN 28, 2020Closed

Referral · Partial · Safety · 27 employees at the site · Closed Aug 5, 2020

9998 Doerr Ln., Schertz, TX 78154 · Petroleum Lubricating Oil and Grease Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 24, 2020: Employee incurs burns and eye damage in breaker arc flash

At 4:30 p.m. on January 24, 2020, an employee was testing a 480 volt breaker to a furnace to determine if it was the cause of the furnace not running. The employee unscrewed conductor wires off the breaker lug when the wires contacted each other and arc flashed. The employee incurred burns to his hands and left eye causing a temporarily clouded eye. The employee was hospitalized and is still experiencing a cloudy eye.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$8,675$5,205Jul 14, 2020Final
Citation 1, item 2a
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$6,940$4,164Jul 14, 2020Final
Citation 1, item 2b
29 CFR 1910.335(b)(1) · Safeguards for personnel protection
Serious$0$0Jul 14, 2020Final
Citation 1, item 3
29 CFR 1910.333(a) · Working near live electrical parts
Serious$8,675$5,205Jul 14, 2020Final
Citation 1, item 4
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$6,940$4,164Jul 14, 2020Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Schertz site logged 1 recordable injury or illness among about 32 workers: 3.0 per 100 full-time workers, against a median of 0.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Axel Royal
Schertz · 2023
32 103.00.6
Axel Royal TX
Schertz · 2020
28 319.70.6

Included with any plan: 3 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 24, 2020, Schertz: Hospitalization · first degree electrical burns · hand(s), unspecified

A maintenance employee was attempting to repair/replace an inoperative breaker to a hot oil furnace when an electrical arc flash occurred, causing first degree burns to the employee's hands.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)

(a) General. Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards.

29 CFR 1910.335 · Safeguards for personnel protection

Other petroleum lubricating oil and grease manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.