OSHA SearchOSHA records by employer

Axip Energy Services, LP: OSHA inspections and violations

Alexander, North Dakota · Natural Gas Distribution · NAICS 221210

1inspections
4citation items
$39,408current penalties
Dec 12, 2023last inspection

Axip Energy Services, LP has one OSHA inspection on record in North Dakota.

OSHA opened it on Dec 12, 2023 as part of a related case, in Alexander.

From that inspection OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

OSHA proposed $39,408 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.147, lockout/tagout (4 items).

For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Axip Energy Services, LP averages $39,408 over 1 cited inspection in that time.

Axip Energy Services, LP: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

North Dakota · latest 90 days of OSHA records

30employers cited

Get notified the morning OSHA posts each new citation in North Dakota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Dakota

Checking a subcontractor, a client or your own company? Watch Axip Energy Services, LP and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347160939 OPENED DEC 12, 2023Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed May 21, 2024

3992 146th Ave Nw, Alexander, ND 58831 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$14,518$14,518Mar 15, 2024Final
Citation 1, item 2a
29 CFR 1910.147(d)(5)(i) · Lockout/tagout
Serious$14,518$14,518Mar 15, 2024Final
Citation 1, item 2b
29 CFR 1910.147(d)(6) · Lockout/tagout
Serious$0$0Mar 15, 2024Final
Citation 1, item 3 Other-than-serious$10,372$10,372Mar 15, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(d)(5)(i)

(5) Stored energy. (i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe.

29 CFR 1910.147(d)(6)

(6) Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.