Inspection 349052530 OPENED JUL 15, 2026Open
821 9th Street, Cheyenne, WY 82001 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
OSHA has inspected Aztec Construction 30 times in Wyoming since 1990.
The latest one began on Jul 15, 2026 as a planned inspection, in Cheyenne; the case is still open.
Those inspections ended with 13 citation items: 7 serious, 1 repeat and 5 other-than-serious.
Penalties were first proposed at $21,159 and now stand at $19,753, 7% lower after settlements or reviews.
Trench protection comes up most often in these citations: 4 items under 1926.652.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Aztec Construction averages $8,182 (2 cited inspections).
Aztec Construction also files yearly injury logs with OSHA, summarized below.
Want to know if OSHA cites Aztec Construction again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company821 9th Street, Cheyenne, WY 82001 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
1922 Newton, Cheyenne, WY 82001 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1153(c)(1) · Silica dust in construction |
Serious | $11,292 | $11,292 | Oct 14, 2025 | Final |
601 W 19th Street, Cheyenne, WY 82001 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
534 Vandehei Ave. And Stockman St., Cheyenne, WY 82007 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4606 Gysel Place, Cheyenne, WY 82009 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $5,072 | $5,072 | Aug 4, 2022 | Final |
1701 Edgewater Avenue, Cheyenne, WY 82009 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4310 Dell Range, Cheyenne, WY 82009 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
624 East 4th, Burns, WY 82053 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.600(a)(5) · Equipment |
Other-than-serious | $0 | $0 | Oct 26, 2009 | Closed |
916 West College Drive, Cheyenne, WY 82007 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.150(c)(1)(viii) · Fire protection |
Other-than-serious | $0 | $0 | May 14, 2009 | Closed |
Holliday Park, Cheyenne, WY 82001 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Unclassified | $3,000 | $2,250 | Sep 21, 2007 | Closed |
Evans & 1st Street, Cheyenne, WY 82001 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7210 Commerce Circle, Cheyenne, WY 82001 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Wydot Facility-5300 Bishop Blvd, Cheyenne, WY 82009 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12th & Kingham Road, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Carla Drive And Ridge Road, Cheyenne, WY 82009 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(j)(2) · Excavations |
Serious | $237 | $237 | Jun 7, 2001 | Closed |
| Citation 1, item 2 29 CFR 1926.651(k)(2) · Excavations |
Serious | $237 | $237 | Jun 7, 2001 | Closed |
| Citation 1, item 3 29 CFR 1926.652(a)(1) · Trench protection |
Repeat | $400 | $400 | Jun 7, 2001 | Closed |
| Citation 2, item 1 29 CFR 1926.1053(b)(16) · Ladders in construction |
Other-than-serious | $0 | $0 | Jun 7, 2001 | Closed |
3702 Dell Range Road, Cheyenne, WY 82009 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Evans Ave. & 21st Street, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
219 West 27th Street, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Randall & 30th Streets, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $47 | $47 | Jul 7, 1999 | Closed |
Melton & Seminole Sts., Cheyenne, WY 82009 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Del Range & Powder House, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4606 North College Drive, Cheyenne, WY 82009 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2301 Central Ave, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
300 E. 23rd Street, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Duff & Pershing Avenues, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pershing Blvd. Between Evans & House, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hugur Ave. & E. Lincolnway, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Serious | $437 | $109 | Jul 14, 1994 | Closed |
| Citation 1, item 2 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $437 | $109 | Jul 14, 1994 | Closed |
Cody Street, Cheyenne, WY 82009 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7210 Commerce Circle, Cheyenne, WY 82001 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Wyoming Air National Guard, Cheyenne, WY 82009 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR CO150002 B04 A |
Other-than-serious | $0 | $0 | Jun 6, 1990 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Cheyenne site logged 6 recordable injuries or illnesses among about 48 workers: 12.8 per 100 full-time workers, against a median of 0.1 for its industry. Those cases cost 42 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Aztec Construction Inc. Cheyenne · 2019 | 48 | 6 | 5 | 12.8 | 0.1 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(16)
(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.
29 CFR 1926.1153(c)(1)
(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.
29 CFR 1926.150(c)(1)(viii)
(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.