OSHA SearchOSHA records by employer

B&B Custom Design LLC: OSHA inspections and violations

Heber City, Utah · Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing · NAICS 335122

1inspections
4citation items
$1,750current penalties
Aug 11, 2020last inspection

B&B Custom Design LLC has one OSHA inspection on record in Utah.

OSHA opened it on Aug 11, 2020 as a planned inspection, in Heber City.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $3,500 in penalties. After settlements and reviews the total is $1,750, down 50%.

Most often, OSHA cited 1910.213, woodworking machinery (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. B&B Custom Design LLC averages $1,750 over 1 cited inspection in that time.

B&B Custom Design LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch B&B Custom Design LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344877097 OPENED AUG 11, 2020Closed

Planned · Partial · Safety · 19 employees at the site · Closed Mar 30, 2021

2875 S Hwy 40, Heber City, UT 84032 · Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,000$1,000Aug 21, 2020Final
Citation 1, item 2a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,500$750Aug 21, 2020Final
Citation 1, item 2b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Aug 21, 2020Final
Citation 1, item 2c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Aug 21, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.