B & B Stucco & Stone Inc: OSHA inspections and violations

St George, Utah · Roofing Contractors · NAICS 238160

3inspections
17citation items
$7,442current penalties
Mar 19, 2015last inspection

OSHA has inspected B & B Stucco & Stone Inc 3 times in Utah since 2000.

The latest one began on Mar 19, 2015 as a planned inspection, in Santa Clara.

Those inspections ended with 17 citation items: 14 serious, 1 repeat and 2 other-than-serious.

Penalties were first proposed at $8,380 and now stand at $7,442, 11% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 10 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and B & B Stucco & Stone Inc averages $938 (1 cited inspection).

B & B Stucco & Stone Inc: OSHA citation items per year, 2000 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

74employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch B & B Stucco & Stone Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340484898 OPENED MAR 19, 2015Closed

Planned · Partial · Safety · 13 employees at the site · Closed Aug 5, 2015

Paradise Village Lot 36, Santa Clara, UT 84765 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$750Jun 23, 2015Final
Citation 1, item 1b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Jun 23, 2015Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$375$188Jun 23, 2015Final

Inspection 304411309 OPENED AUG 30, 2001Closed

Planned · Complete · Safety · 16 employees at the site · Closed Dec 1, 2001

1685 N Sonoran Dr, St George, UT 84770 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$1,500$1,500Oct 24, 2001Closed
Citation 2, item 1a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$875$875Oct 24, 2001Closed
Citation 2, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Oct 24, 2001Closed
Citation 2, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Oct 24, 2001Closed
Citation 2, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$875$875Oct 24, 2001Closed
Citation 2, item 2b
29 CFR 1926.454(c)(3) · Scaffold training
Serious$0$0Oct 24, 2001Closed
Citation 3, item 1
29 CFR 10008 C01
Other-than-serious$250$250Oct 24, 2001Closed

Inspection 301169264 OPENED APR 4, 2000Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 30, 2005

Lot #13, 1854 W. Stonebridge Dr, St George, UT 84770 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,380$1,380Jun 13, 2000Closed
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Jun 13, 2000Closed
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,625$1,625Jun 13, 2000Closed
Citation 1, item 2b
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Jun 13, 2000Closed
Citation 1, item 2c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jun 13, 2000Closed
Citation 1, item 2d
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jun 13, 2000Closed
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Jun 13, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.454 · Scaffold training