OSHA SearchOSHA records by employer

B&D Contractors, Inc.: OSHA inspections and violations

Milwaukee, Wisconsin · Commercial and Institutional Building Construction · NAICS 236220

7inspections
4citation items
$4,968current penalties
Aug 14, 2018last inspection

Since 1992, OSHA inspectors have visited B&D Contractors, Inc. in Wisconsin 7 times.

The most recent inspection opened on Aug 14, 2018 as a planned inspection, in Milwaukee.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $6,297; today they stand at $4,968, 21% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. B&D Contractors, Inc. averages $3,100 across 1 cited inspection.

B&D Contractors, Inc.: OSHA citation items per year, 1992 to 2018
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

228employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch B&D Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343384459 OPENED AUG 14, 2018Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jul 5, 2019

1500 W. North Ave, Milwaukee, WI 53205 · Glass and Glazing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,772$3,100Aug 17, 2018Final

Inspection 307059121 OPENED JAN 12, 2005Closed

Planned · Partial · Safety · 40 employees at the site · Closed Feb 10, 2005

8110 W. Brown Deer Rd., Milwaukee, WI 53223 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$525$368Jan 21, 2005Closed

Inspection 305280026 OPENED SEP 15, 2003Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Oct 21, 2003

2816 W. Clarke Street, Milwaukee, WI 53210 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303320592 OPENED APR 4, 2001Closed

Planned · Partial · Safety · 3 employees at the site · Closed May 22, 2001

Boston Store- Wisconsin Ave., Milwaukee, WI 53203 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$1,750$900Apr 16, 2001Closed
Citation 1, item 2
29 CFR 1926.452(w)(1) · Rules for each type of scaffold
Serious$1,250$600Apr 16, 2001Closed

Inspection 300120714 OPENED JAN 11, 2000Closed

Referral · Partial · Safety · 30 employees at the site · Closed Jan 26, 2000

Laptham Apartments - North 6th Street, Milwaukee, WI 53212 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300119757 OPENED JUL 13, 1999Closed

Unprogrammed related · Partial · Safety · 31 employees at the site · Closed Jan 12, 2000

Miller Park Baseball Stadium, Milwaukee, WI 53214 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 102976107 OPENED FEB 5, 1992Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 10, 1992

Laptham Apartments - North 6th Street, Milwaukee, WI 53212 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(xv)

(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(w)(1)

(w) Mobile scaffolds. (1) Scaffolds shall be braced by cross, horizontal, or diagonal braces, or combination thereof, to prevent racking or collapse of the scaffold and to secure vertical members together laterally so as to automatically square and align the vertical members. Scaffolds shall be plumb, level, and squared. All brace connections shall be secured.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.503 · Fall protection training in construction

Other commercial and institutional building construction employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.