OSHA SearchOSHA records by employer

B & Z Plastering, Inc.: OSHA inspections and violations

Pittsburgh, Pennsylvania · Masonry Contractors · NAICS 238140

1inspections
4citation items
$6,312current penalties
Jan 31, 2018last inspection

OSHA has inspected B & Z Plastering, Inc. once in Pennsylvania.

The inspection began on Jan 31, 2018 on a referral, in Pittsburgh.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $9,423 and now stand at $6,312, 33% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and B & Z Plastering, Inc. averages $6,312 (1 cited inspection).

B & Z Plastering, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

280employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch B & Z Plastering, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342924388 OPENED JAN 31, 2018Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jul 25, 2023

7204 Old Mcknight Road Ross Township, Pittsburgh, PA 15205 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,880$2,600Mar 5, 2018Final
Citation 1, item 1b
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Mar 5, 2018Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,880$2,600Mar 5, 2018Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$1,663$1,112Mar 5, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.451(h)(2)(ii)

(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.