OSHA SearchOSHA records by employer

B - B Stucco and Stone LLC: OSHA inspections and violations

Waxhaw, North Carolina · Masonry Contractors · NAICS 238140

1inspections
5citation items
$4,200current penalties
Oct 9, 2018last inspection

OSHA inspectors have visited B - B Stucco and Stone LLC in North Carolina one time.

It opened on Oct 9, 2018 as a planned inspection, in Waxhaw.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $4,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. B - B Stucco and Stone LLC averages $4,200 across 1 cited inspection.

B - B Stucco and Stone LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch B - B Stucco and Stone LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343522512 OPENED OCT 9, 2018Closed

Planned · Partial · Safety · 10 employees at the site · Closed Feb 27, 2019

The Meadows At Weddington, 128 Verbena Ct. Lot 25, Waxhaw, NC 28173 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,100$2,100Jan 7, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jan 7, 2019Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,100$2,100Jan 7, 2019Final
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jan 7, 2019Final
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jan 7, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other masonry contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.