Inspection 341172039 OPENED JAN 12, 2016Closed
60490 Bobcat Rd, Bend, OR 97702 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1987, OSHA inspectors have visited Babcock Bros Inc in Oregon 24 times.
The most recent inspection opened on Jan 12, 2016 to follow up on an earlier case, in Bend.
In all, OSHA issued 43 citation items: 22 serious, 2 repeat and 19 other-than-serious.
The penalties, $6,830 in total, stand where OSHA first set them.
The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Babcock Bros Inc averages $3,200 across 1 cited inspection.
Oregon · latest 90 days of OSHA records
396employers cited
18 of them in the same industry
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch Babcock Bros Inc and get notified the morning OSHA posts a new citation for it.
Watch this company60490 Bobcat Rd, Bend, OR 97702 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
60490 Bobcat Rd, Bend, OR 97702 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR OAR 437-003-0094(1)-3 |
Serious | $1,400 | $1,400 | Dec 28, 2015 | Final |
| Citation 1, item 2 29 CFR OAR 437-003-1501(2) |
Serious | $840 | $840 | Dec 28, 2015 | Final |
| Citation 1, item 3a 29 CFR 1926.405(g)(2)(v) · Job-site wiring |
Serious | $840 | $840 | Dec 28, 2015 | Final |
| Citation 1, item 3b 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $0 | $0 | Dec 28, 2015 | Final |
| Citation 1, item 4 29 CFR OAR 437-003-0404(3)(C)-2 |
Serious | $120 | $120 | Dec 28, 2015 | Final |
| Citation 2, item 5 29 CFR 1926.150(c)(1)(viii) · Fire protection |
Other-than-serious | $0 | $0 | Dec 28, 2015 | Final |
| Citation 2, item 6 29 CFR OAR 437-001-0765(13)-1 |
Other-than-serious | $0 | $0 | Dec 28, 2015 | Final |
175 Ne Greenwood, Bend, OR 97701 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $100 | $100 | Oct 21, 2010 | Closed |
Corner Of Parrell Rd & Badger Rd, Bend, OR 97701 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Maple Ave & 22nd St, Redmond, OR 97756 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $100 | $100 | Apr 7, 2006 | Closed |
61736 Pettigrew Rd, Bend, OR 97702 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.602(a)(9)(ii) · Earthmovers and forklifts in construction |
Serious | $180 | $180 | Mar 24, 2004 | Closed |
23rd & Elm, Redmond, OR 97756 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1052(c)(1) · Stairways in construction |
Other-than-serious | $0 | $0 | Mar 17, 2004 | Closed |
2690 Ne 2nd St, Bend, OR 97701 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Repeat | $200 | $200 | Mar 17, 2004 | Closed |
| Citation 1, item 2 | Repeat | $200 | $200 | Mar 17, 2004 | Closed |
| Citation 2, item 3 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 17, 2004 | Closed |
| Citation 2, item 4 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Other-than-serious | $0 | $0 | Mar 17, 2004 | Closed |
301 Ne Addison, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
301 Ne Addison, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Corner Of Dean Swift And Hwy 20 East, Bend, OR 97702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $180 | $180 | Sep 5, 2001 | Closed |
| Citation 2, item 2 29 CFR 1926.1053(b)(4) · Ladders in construction |
Other-than-serious | $0 | $0 | Sep 5, 2001 | Closed |
| Citation 2, item 3 29 CFR 1926.1053(b)(1) · Ladders in construction |
Other-than-serious | $0 | $0 | Sep 5, 2001 | Closed |
301 Ne Addison, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $270 | $270 | Sep 5, 2001 | Closed |
| Citation 2, item 2 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Sep 5, 2001 | Closed |
| Citation 2, item 3 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Sep 5, 2001 | Closed |
| Citation 2, item 4 | Other-than-serious | $0 | $0 | Sep 5, 2001 | Closed |
392 Soft Tail Lp, Bend, OR 97702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.602(a)(9)(i) · Earthmovers and forklifts in construction |
Other-than-serious | $0 | $0 | Aug 2, 2001 | Closed |
301 Ne Addison, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.59(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | May 23, 2001 | Closed |
3343 Windwood, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $100 | $100 | May 9, 2001 | Closed |
37 Winners Circle, Sunriver, OR 97707 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.59(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 8, 2000 | Closed |
Lot # 30 Sunset View, Bend, OR 97702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $825 | $825 | Mar 22, 2000 | Closed |
| Citation 1, item 1b 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 22, 2000 | Closed |
| Citation 1, item 1c 29 CFR 1926.451(b)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 22, 2000 | Closed |
| Citation 2, item 2 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Mar 22, 2000 | Closed |
Foley & Silvies Bridges E Of, Burns, OR 97720 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.601(b)(14) · Motor vehicles |
Other-than-serious | $0 | $0 | Dec 29, 1998 | Closed |
2457 Desert Willow Dr, Bend, OR 97708 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $180 | $180 | Apr 17, 1998 | Closed |
| Citation 1, item 1b 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $0 | $0 | Apr 17, 1998 | Closed |
| Citation 1, item 1c 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $0 | $0 | Apr 17, 1998 | Closed |
| Citation 1, item 2 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $180 | $180 | Apr 17, 1998 | Closed |
23rd & Antler Ave, Redmond, OR 97756 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(k)(1) · Excavations |
Serious | $275 | $275 | Aug 29, 1997 | Closed |
6805 Nightfall Cir, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $100 | $100 | Aug 7, 1996 | Closed |
| Citation 2, item 2 29 CFR 1926.300(a) · Tools—Hand and Power: general requirements |
Other-than-serious | $0 | $0 | Aug 7, 1996 | Closed |
| Citation 2, item 3 | Other-than-serious | $0 | $0 | Aug 7, 1996 | Closed |
Mt Bachelor Village, Bend, OR 97702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1052(c)(1) · Stairways in construction |
Serious | $120 | $120 | Apr 21, 1995 | Closed |
| Citation 1, item 2 29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $120 | $120 | Apr 21, 1995 | Closed |
| Citation 2, item 3 | Other-than-serious | $500 | $500 | Apr 21, 1995 | Closed |
North Side Of Butler Market Rd East Of Yeoman Rd, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
61220 S Highway 97, Bend, OR 97702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7831843 |
Other-than-serious | $0 | $0 | Nov 9, 1987 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.213(c)(1)
(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po
29 CFR 1910.215(a)(4)
(4) Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.
29 CFR 1910.215(b)(9)
(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.