OSHA SearchOSHA records by employer

Bachman's Roofing, Building & Remodeling, Inc.: OSHA inspections and violations

Wyomissing, Pennsylvania · Roofing Contractors · NAICS 238160

9inspections
11citation items
$55,806current penalties
Apr 30, 2024last inspection

Bachman's Roofing, Building & Remodeling, Inc. has 9 OSHA inspections on record in Pennsylvania, the first in 2014.

OSHA's last visit started on Apr 30, 2024 on a referral, in Breinigsville.

Across those inspections OSHA issued 11 citation items: 8 serious, 2 repeat and 1 other-than-serious.

OSHA proposed $109,955 in penalties. After settlements and reviews the total is $55,806, down 49%.

Most often, OSHA cited 1926.501, fall protection in construction (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Bachman's Roofing, Building & Remodeling, Inc. averages $13,789 over 3 cited inspections in that time.

Bachman's Roofing, Building & Remodeling, Inc. also files yearly injury logs with OSHA, summarized below.

Bachman's Roofing, Building & Remodeling, Inc.: OSHA citation items per year, 2014 to 2024
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

274employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Bachman's Roofing, Building & Remodeling, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347447070 OPENED APR 30, 2024Closed

Referral · Partial · Safety · 2 employees at the site · Closed Sep 19, 2024

1024 Sparrow Way, Breinigsville, PA 18031 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$14,518$12,000Jul 11, 2024Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Jul 11, 2024Final

Inspection 346275035 OPENED OCT 12, 2022Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Jan 13, 2023

4016 Lilac Street, Allentown, PA 18103 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345217657 OPENED MAR 22, 2021Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Nov 29, 2022

320-328 Newport Place, Exton, PA 19341 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341693745 OPENED AUG 11, 2016Closed

Referral · Partial · Safety · 85 employees at the site · Closed Oct 4, 2018

3000 Regency Drive, Sinking Spring, PA 19608 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$48,013$12,471Sep 22, 2016Final
Citation 1, item 2
29 CFR 1926.1060(b) · Ladder and stairway training
Serious$10,974$5,345Sep 22, 2016Final

Inspection 341126795 OPENED DEC 16, 2015Closed

Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Jun 2, 2016

100 Independence Court, Blandon, PA 19510 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$19,250$11,550Apr 1, 2016Final

Inspection 340142850 OPENED DEC 16, 2014Closed

Referral · Partial · Safety · 20 employees at the site · Closed Feb 24, 2015

1222 Delaware Ave, Wyomissing, PA 19610 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$6,160$6,160Jan 28, 2015Final

Inspection 339808719 OPENED JUN 10, 2014Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Aug 8, 2014

1680 East Thistle Drive, Wyomissing, PA 19610 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$1,500Jul 18, 2014Final
Citation 1, item 2
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$2,000$1,500Jul 18, 2014Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$1,500Jul 18, 2014Final

Inspection 339802613 OPENED JUN 9, 2014Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Aug 22, 2014

1513 Cromwell Street, Wyomissing, PA 19610 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,520$1,890Jul 18, 2014Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,520$1,890Jul 18, 2014Final
1 older inspection

Inspection 339643579 OPENED MAR 21, 2014Closed

Planned · Complete · Safety · 4 employees at the site · Closed Mar 24, 2014

68 Werner Street, Wernersville, PA 19565 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Wernersville site logged 3 recordable injuries or illnesses among about 110 workers: 5.6 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 66 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Bachman's Roofing, Building & Remodeling LLC.
Wernersville · 2025
110 325.62.8
Bachman's Roofing, Building & Remodeling Inc.
Wernersville · 2024
110 110.92.8
Bachman's Roofing, Building & Remodeling, Inc.
Wernersville · 2023
120 543.62.8

Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(b)

(b) Retraining shall be provided for each employee as necessary so that the employee maintains the understanding and knowledge acquired through compliance with this section.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other roofing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.