OSHA SearchOSHA records by employer

Baco, Inc.: OSHA inspections and violations

Nashville, Tennessee · Masonry Contractors · NAICS 238140

10inspections
20citation items
$11,550current penalties
Oct 22, 2015last inspection

OSHA has inspected Baco, Inc. 10 times in Tennessee since 1996.

The latest one began on Oct 22, 2015 as a planned inspection, in Dickson.

Those inspections ended with 20 citation items: 16 serious and 4 other-than-serious.

Penalties were first proposed at $11,550 and still stand at $11,550.

Scaffolds, general requirements comes up most often in these citations: 10 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Baco, Inc. averages $900 (1 cited inspection).

Baco, Inc.: OSHA citation items per year, 1996 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Baco, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341022275 OPENED OCT 22, 2015Closed

Planned · Complete · Safety · 20 employees at the site · Closed Dec 7, 2015

55 Thornton Dr., Dickson, TN 37055 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$900$900Nov 12, 2015Final

Inspection 316553825 OPENED MAY 4, 2012Closed

Planned · Complete · Safety · 10 employees at the site · Closed Aug 15, 2013

800 Hwy 76, White House, TN 37188 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,200$1,200Jun 7, 2012Closed

Inspection 314647041 OPENED JUN 4, 2010Closed

Planned · Complete · Safety · 5 employees at the site · Closed Oct 18, 2010

3715 Crestview Drive, Nashville, TN 37215 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,750$1,750Jul 12, 2010Closed

Inspection 314397589 OPENED MAY 25, 2010Closed

Planned · Complete · Safety · 20 employees at the site · Closed Sep 30, 2010

2650 New Salem Hwy, Murfreesboro, TN 37128 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$1,050Jul 14, 2010Closed
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,050$1,050Jul 14, 2010Closed
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$1,050$1,050Jul 14, 2010Closed

Inspection 312421456 OPENED AUG 13, 2008Closed

Planned · Complete · Safety · 25 employees at the site · Closed Apr 14, 2009

11207 Lebanon Rd, Mount Juliet, TN 37122 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,050$1,050Oct 2, 2008Closed
Citation 1, item 1b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Oct 2, 2008Closed
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 2, 2008Closed
Citation 1, item 1d
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Oct 2, 2008Closed
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$150$150Oct 2, 2008Closed

Inspection 311147219 OPENED JUL 13, 2007Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed Oct 2, 2007

4175 Franklin Rd, Murfreesboro, TN 37128 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,750$1,750Aug 7, 2007Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 7, 2007Closed
Citation 1, item 1c
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Aug 7, 2007Closed

Inspection 309930139 OPENED JUN 30, 2006Closed

Planned · Complete · Safety · 8 employees at the site · Closed Feb 14, 2007

2000 Belshire Way, Spring Hill, TN 37174 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.454(a) · Scaffold training
Serious$750$750Jul 26, 2006Closed

Inspection 309225282 OPENED AUG 3, 2005Closed

Planned · Complete · Safety · 10 employees at the site · Closed Sep 23, 2005

701 Bear Creek Pike, Columbia, TN 38401 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$600$600Aug 29, 2005Closed
2 older inspections

Inspection 302483581 OPENED APR 22, 1999Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jul 30, 1999

Hwy 70, Dickson, TN 37055 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(g)(1) · Hazard communication
Other-than-serious$0$0Jun 22, 1999Closed

Inspection 127316024 OPENED APR 17, 1996Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 5, 1996

78 Lafayette, Nashville, TN 37210 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$250$250May 3, 1996Closed
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0May 3, 1996Closed
Citation 2, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0May 3, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

Other masonry contractors employers in Tennessee