OSHA SearchOSHA records by employer

Baker Refrigeration Systems, Inc.: OSHA inspections and violations

Mount Pleasant, Texas · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
2citation items
$10,446current penalties
Jan 27, 2021last inspection

Baker Refrigeration Systems, Inc. has 2 OSHA inspections on record in Texas, the first in 2012.

OSHA's last visit started on Jan 27, 2021 after a fatality or catastrophe, in Waco.

Across those inspections OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

OSHA proposed $12,357 in penalties. After settlements and reviews the total is $10,446, down 15%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Baker Refrigeration Systems, Inc. averages $7,646 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Baker Refrigeration Systems, Inc.: OSHA citation items per year, 2012 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Baker Refrigeration Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345119630 OPENED JAN 27, 2021Closed

Fatality or catastrophe · Partial · Safety · 71 employees at the site · Closed Apr 21, 2021

2500 E. Lakeshore Dr., Waco, TX 76705 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 26, 2021 (fatal): Employee falls and is killed

At 7:30 a.m. on January 26, 2021, an employee worked with coworkers in an attic space to conducted demolition of old ammonia pipes for a renovation project. At some point, the employee fell approximately ten feet through the attic walking/working surface composed of ceiling tiles and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(a)(2) · Fall protection in construction
Serious$9,557$7,646Mar 1, 2021Final

Inspection 336031984 OPENED AUG 24, 2012Closed

Unprogrammed related · Partial · Safety · 42 employees at the site · Closed Dec 10, 2012

1000 Pilgrim Street, Mount Pleasant, TX 75456 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$2,800$2,800Nov 13, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(a)(2)

(2) The employer shall determine if the walking/working surfaces on which its employees are to work have the strength and structural integrity to support employees safely. Employees shall be allowed to work on those surfaces only when the surfaces have the requisite strength and structural integrity.

Other plumbing, heating, and air-conditioning contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.