OSHA SearchOSHA records by employer

Baltimore Aircoil Company, Inc.: OSHA inspections and violations

Dayton, Tennessee · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

2inspections
4citation items
$7,700current penalties
Jun 17, 2024last inspection

OSHA has inspected Baltimore Aircoil Company, Inc. 2 times in Tennessee since 2024.

The latest one began on Jun 17, 2024 on a referral, in Dayton; the case is still open.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $7,700 and still stand at $7,700.

Lockout/tagout comes up most often in these citations: 4 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Baltimore Aircoil Company, Inc. averages $7,700 (1 cited inspection).

Baltimore Aircoil Company, Inc. also files yearly injury logs with OSHA, summarized below.

Baltimore Aircoil Company, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

335employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Baltimore Aircoil Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Baltimore Aircoil Company, Inc. at 3 sites in 3 states. Together they've had 24 inspections and $61,835 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 347569956 OPENED JUN 17, 2024Open

Referral · Partial · Safety · 262 employees at the site · Open

990 Manufacturers Road, Dayton, TN 37321 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$3,200$3,200Sep 25, 2024Contested
Citation 1, item 2a
29 CFR 1910.147(d)(2) · Lockout/tagout
Serious$4,500$4,500Sep 25, 2024Contested
Citation 1, item 2b
29 CFR 1910.147(d)(3) · Lockout/tagout
Serious$0$0Sep 25, 2024Contested
Citation 1, item 2c
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Sep 25, 2024Contested

Inspection 347447609 OPENED APR 30, 2024Closed

Complaint · Partial · Health · 220 employees at the site · Closed Jul 18, 2024

990 Manufacturers Rd, Dayton, TN 37321 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Dayton site logged 10 recordable injuries or illnesses among about 375 workers: 2.8 per 100 full-time workers, against a median of 2.4 for its industry. Those cases cost 9 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Baltimore Aircoil Company
Dayton · 2025
375 1032.82.4

Included with any plan: 1 more yearly log from these sites, back to 2023, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

29 CFR 1910.147(d)(2)

(2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.

29 CFR 1910.147(d)(3)

(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.