OSHA SearchOSHA records by employer

Barbizon Charlotte, Inc.: OSHA inspections and violations

Atlanta, Georgia · Other Lighting Equipment Manufacturing · NAICS 335129

1inspections
3citation items
$85,000current penalties
Oct 31, 2024last inspection

OSHA has inspected Barbizon Charlotte, Inc. once in Georgia.

The inspection began on Oct 31, 2024 on a referral, in Atlanta.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $135,721 and now stand at $85,000, 37% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Barbizon Charlotte, Inc. averages $85,000 (1 cited inspection).

Barbizon Charlotte, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Barbizon Charlotte, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347856320 OPENED OCT 31, 2024Closed

Referral · Partial · Safety · 45 employees at the site · Closed Sep 18, 2026

3434 Roswell Rd Nw, Atlanta, GA 30305 · Other Lighting Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.454(b) · Scaffold training
Serious$11,585$8,000Feb 24, 2025Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$8,276$6,000Feb 24, 2025Final
Citation 2, item 1
29 CFR 1926.452(w)(6)(iii) · Rules for each type of scaffold
Serious$115,860$71,000Feb 24, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(w)(6)(iii)

(iii) Outrigger frames, when used, are installed on both sides of the scaffold;

29 CFR 1926.454 · Scaffold training

29 CFR 1926.454(b)

(b) The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. The training shall include the following topics, as applicable:

Other other lighting equipment manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.