OSHA SearchOSHA records by employer

Barker Fire Department: OSHA inspections and violations

Barker, New York · Fire Protection · NAICS 922160

5inspections
7citation items
$0current penalties
Sep 3, 2021last inspection

OSHA has inspected Barker Fire Department 5 times in New York since 2018.

The latest one began on Sep 3, 2021 as part of a related case, in Barker.

Those inspections ended with 7 citation items: 6 serious and 1 other-than-serious.

None of the citations carried a penalty.

How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and Barker Fire Department averages $0 (1 cited inspection).

Barker Fire Department: OSHA citation items per year, 2018 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Barker Fire Department and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345588271 OPENED SEP 3, 2021Closed

Unprogrammed related · Partial · Safety · Local government · 40 employees at the site · Closed Jun 30, 2022

1660 Quaker Road, Barker, NY 14012 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343776613 OPENED JAN 17, 2019Closed

Follow-up · Partial · Safety · Local government · 45 employees at the site · Closed Jan 17, 2019

1660 Quaker Road, Barker, NY 14012 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343710489 OPENED NOV 29, 2018Closed

Monitoring · Partial · Safety · Local government · 45 employees at the site · Closed Nov 29, 2018

1660 Quaker Road, Barker, NY 14012 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343504593 OPENED SEP 27, 2018Closed

Monitoring · Partial · Safety · Local government · 45 employees at the site · Closed Sep 27, 2018

1660 Quaker Road, Barker, NY 14012 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343293767 OPENED JUL 12, 2018Closed

Planned · Complete · Safety · Local government · 45 employees at the site · Closed Jan 17, 2019

1660 Quaker Road, Barker, NY 14012 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 12 NYCRR PART 800.6(E)
Serious$0$0Aug 22, 2018Final
Citation 1, item 2
29 CFR 12 NYCRR PART 800.7(F)(1)
Serious$0$0Aug 22, 2018Final
Citation 1, item 3
29 CFR 1910.179(j)(4)(iii) · Overhead and gantry cranes
Serious$0$0Aug 22, 2018Final
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Aug 22, 2018Final
Citation 1, item 5
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Aug 22, 2018Final
Citation 1, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Aug 22, 2018Final
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Aug 22, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(4)(iii)

(iii) Standby cranes shall be inspected at least semi-annually in accordance with requirements of paragraph (j)(2) of this section and paragraph (m)(2) of this section.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other fire protection employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.