OSHA SearchOSHA records by employer

Barrett Interiors, Inc.: OSHA inspections and violations

St. Francisville, Louisiana · Masonry Contractors · NAICS 238140

4inspections
6citation items
$1,755current penalties
Apr 21, 2015last inspection

OSHA has inspected Barrett Interiors, Inc. 4 times in Louisiana since 1991.

The latest one began on Apr 21, 2015 as a planned inspection, in Destrehan.

Those inspections ended with 6 citation items: 4 serious and 2 other-than-serious.

Penalties were first proposed at $2,885 and now stand at $1,755, 39% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Barrett Interiors, Inc. averages $1,200 (1 cited inspection).

Barrett Interiors, Inc.: OSHA citation items per year, 1991 to 2015
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

19employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Barrett Interiors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340587146 OPENED APR 21, 2015Closed

Planned · Partial · Safety · 11 employees at the site · Closed Oct 21, 2015

13100 River Rd., Destrehan, LA 70047 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,000$1,200Sep 21, 2015Final

Inspection 303084388 OPENED FEB 26, 2001Closed

Planned · Complete · Safety · 12 employees at the site · Closed Mar 4, 2002

601 N. Oak St., Hammond, LA 70401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Other-than-serious$0$0Mar 8, 2001Closed

Inspection 301988879 OPENED FEB 17, 1998Closed

Planned · Partial · Safety · 6 employees at the site · Closed Apr 14, 1998

346 Civic Center Blvd., Houma, LA 70360 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$525$315Feb 26, 1998Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$300$180Feb 26, 1998Closed
Citation 2, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Feb 26, 1998Closed

Inspection 108914045 OPENED FEB 26, 1991Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 28, 1991

Hwy 61 & Bainer Ristroph Rd., St. Francisville, LA 70775 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$60$60Apr 2, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(4)

(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other masonry contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.