OSHA SearchOSHA records by employer

Basc MFG Inc: OSHA inspections and violations

Walled Lake, Michigan · Showcase, Partition, Shelving, and Locker Manufacturing · NAICS 337215

3inspections
27citation items
$1,980current penalties
Feb 29, 2024last inspection

Since 2019, OSHA inspectors have visited Basc MFG Inc in Michigan 3 times.

The most recent inspection opened on Feb 29, 2024 as a planned inspection, in Walled Lake.

In all, OSHA issued 27 citation items: 12 serious, 1 repeat and 14 other-than-serious.

The proposed penalties came to $3,960; today they stand at $1,980, 50% less.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Basc MFG Inc averages $660 across 3 cited inspections.

Basc MFG Inc: OSHA citation items per year, 2019 to 2024
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

656employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Basc MFG Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347311995 OPENED FEB 29, 2024Closed

Planned · Complete · Safety · 10 employees at the site · Closed May 22, 2024

4325 Martin Rd, Walled Lake, MI 48390 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10114(1)
Serious$400$200Apr 26, 2024Final
Citation 1, item 2
29 CFR 408.11223(1)
Serious$400$200Apr 26, 2024Final
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Apr 26, 2024Final
Citation 2, item 2
29 CFR 408.12154(5)
Other-than-serious$0$0Apr 26, 2024Final

Inspection 344029509 OPENED MAY 23, 2019Closed

Unprogrammed other · Partial · Health · 1 employee at the site · Closed Sep 24, 2019

4325 Martin Rd, Walled Lake, MI 48390 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Aug 29, 2019Final

Inspection 343950226 OPENED APR 22, 2019Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jul 24, 2019

4325 Martin Rd, Walled Lake, MI 48390 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(e)(1)(vii) · Ladders in general industry
Serious$500$250Jun 17, 2019Final
Citation 1, item 2a
29 CFR 408.12154(1)
Serious$500$250Jun 17, 2019Final
Citation 1, item 2b
29 CFR 408.12131(1)
Serious$0$0Jun 17, 2019Final
Citation 1, item 3a
29 CFR 408.12645(1)
Serious$500$250Jun 17, 2019Final
Citation 1, item 3b
29 CFR 408.12617(2)
Serious$0$0Jun 17, 2019Final
Citation 1, item 4
29 CFR 408.12728(1)
Serious$500$250Jun 17, 2019Final
Citation 1, item 5a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$500$250Jun 17, 2019Final
Citation 1, item 5b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jun 17, 2019Final
Citation 1, item 6a
29 CFR 408.15815(1)
Serious$500$250Jun 17, 2019Final
Citation 1, item 6b
29 CFR 408.15815(9)
Serious$0$0Jun 17, 2019Final
Citation 2, item 1a
29 CFR 408.10015(1)
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 1b
29 CFR 408.10033(1)
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 2a
29 CFR 408.10831(1)
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 2b
29 CFR 408.10833(1)
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 3
29 CFR 408.13308(3)
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 4a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 4b
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 4c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 5
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 17, 2019Final
Citation 2, item 7
29 CFR 325.47201(3)
Other-than-serious$0$0Jun 17, 2019Final
Citation 3, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Repeat$160$80Jun 17, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(k)(6)

(6) The basic advisory information on respirators, as presented in appendix D of this section, shall be provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods