OSHA SearchOSHA records by employer

BB&S Acquisition LLC: OSHA inspections and violations

North Kingstown, Rhode Island · Wood Preservation · NAICS 321114

1inspections
4citation items
$7,264current penalties
Jan 13, 2026last inspection

BB&S Acquisition LLC has one OSHA inspection on record in Rhode Island.

OSHA opened it on Jan 13, 2026 as a planned inspection, in North Kingstown.

From that inspection OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

OSHA proposed $12,106 in penalties. After settlements and reviews the total is $7,264, down 40%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. BB&S Acquisition LLC averages $7,264 over 1 cited inspection in that time.

BB&S Acquisition LLC also files yearly injury logs with OSHA, summarized below.

BB&S Acquisition LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

83employers cited

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch BB&S Acquisition LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348682600 OPENED JAN 13, 2026Closed

Planned · Complete · Safety · 43 employees at the site · Closed Sep 14, 2026

61 Bonneau Road, North Kingstown, RI 02852 · Wood Preservation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$5,979$3,587Mar 16, 2026Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$4,783$2,870Mar 16, 2026Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$672$403Mar 16, 2026Final
Citation 2, item 2
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$672$403Mar 16, 2026Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the North Kingstown site logged 4 recordable injuries or illnesses among about 43 workers: 8.4 per 100 full-time workers, against a median of 4.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
BB&S Treated Lumber of New England
North Kingstown · 2023
43 408.44.2

Included with any plan: 3 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(1)(iv)(a)

(A) As a substitute for the fixed wiring of a structure;

29 CFR 1910.334 · Using electrical equipment

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.