OSHA SearchOSHA records by employer

Bearhawk Inc: OSHA inspections and violations

Central Point, Oregon · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

2inspections
9citation items
$4,898current penalties
Oct 4, 2024last inspection

Bearhawk Inc has 2 OSHA inspections on record in Oregon, the first in 2005.

OSHA's last visit started on Oct 4, 2024 after a complaint, in Gresham, and the case has not closed yet.

Across those inspections OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

OSHA proposed $4,898 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Bearhawk Inc averages $3,458 over 1 cited inspection in that time.

Bearhawk Inc: OSHA citation items per year, 2005 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Bearhawk Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347800294 OPENED OCT 4, 2024Open

Complaint · Partial · Safety · 8 employees at the site · Open

2950 Ne 23rd St, Gresham, OR 97030 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,458$3,458Dec 2, 2024Final
Citation 2, item 2
29 CFR OAR 437-001-0765(13)-1
Other-than-serious$0$0Dec 2, 2024Final

Inspection 308419035 OPENED JUN 14, 2005Closed

Planned · Partial · Safety · 7 employees at the site · Closed Nov 10, 2005

4999 Biddle Rd, Central Point, OR 97502 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(4)(iii) · Scaffolds, general requirements
Serious$900$900Jul 8, 2005Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jul 8, 2005Closed
Citation 1, item 1c
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Jul 8, 2005Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$180$180Jul 8, 2005Closed
Citation 1, item 3a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$180$180Jul 8, 2005Closed
Citation 1, item 3b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Jul 8, 2005Closed
Citation 1, item 4
29 CFR 7031501
Serious$180$180Jul 8, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.452 · Rules for each type of scaffold