8inspections
26citation items
$11,142current penalties
Jun 27, 2025last inspection

OSHA has inspected Bel Air Foam & Roofing, Inc. 8 times in Maryland since 2010.

The latest one began on Jun 27, 2025 as a planned inspection, in Bel Air.

Those inspections ended with 26 citation items: 12 serious, 1 repeat and 13 other-than-serious.

Penalties were first proposed at $16,825 and now stand at $11,142, 34% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 8 items under 1910.134.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Bel Air Foam & Roofing, Inc. averages $1,736 (5 cited inspections).

1 inspection on this page followed a fatal incident.

Bel Air Foam & Roofing, Inc.: OSHA citation items per year, 2010 to 2025
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

180employers cited

31 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Bel Air Foam & Roofing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348339383 OPENED JUN 27, 2025Closed

Planned · Complete · Safety · 9 employees at the site · Closed Sep 17, 2025

2005 Churchville Road, Bel Air, MD 21015 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,200$720Jul 28, 2025Final

Inspection 345818470 OPENED MAR 7, 2022Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 16, 2022

9518 Philadelphia Road, Rosedale, MD 21237 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,050$756Apr 19, 2022Final

Inspection 343330999 OPENED JUL 26, 2018Closed

Fatality or catastrophe · Complete · Safety · 6 employees at the site · Closed Feb 13, 2019

211 E. Pleasant Street, Baltimore, MD 21202 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 26, 2018 (fatal): Employee falls from roof and is killed

At 7:00 a.m. on July 26, 2018, an employee and his coworker were rolling a cart that contained a roll of roofing material down a 3:12 sloped roof with a 30 inch parapet. During movement of the material, the coworker slipped and the cart started to roll free down the roof. The employee reached to stop the cart and fell over the edge of the roof. The employee struck a concrete sidewalk that was 70 feet below the roof and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$1,225$662Jan 22, 2019Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,050$1,647Jan 22, 2019Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,225$772Jan 22, 2019Final
Citation 2, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Jan 22, 2019Final

Inspection 342749181 OPENED NOV 2, 2017Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 8, 2018

1740 E. Joppa Rd., Parkville, MD 21234 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$225$225Jan 18, 2018Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$225$225Jan 18, 2018Final

Inspection 341223055 OPENED FEB 2, 2016Open

Planned · Complete · Safety · 5 employees at the site · Open

1480 Berger Street, Odenton, MD 21113 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$875$875Mar 17, 2016Contested
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$2,800$2,800Mar 17, 2016Contested
Citation 3, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Mar 17, 2016Contested

Inspection 317586022 OPENED JAN 13, 2014Closed

Planned · Complete · Safety · 5 employees at the site · Closed May 14, 2014

2100 Emmorton Road, Bel Air, MD 21015 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$900$900Mar 11, 2014Closed

Inspection 314408378 OPENED JUN 29, 2010Closed

Referral · Partial · Health · 9 employees at the site · Closed Mar 31, 2014

210 Research Boulevard, Aberdeen, MD 21001 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$1,050$0Oct 6, 2010Closed
Citation 1, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Oct 6, 2010Closed
Citation 1, item 1c
29 CFR 1910.134(d)(3)(iiib)(2) · Respiratory protection
Other-than-serious$0$0Oct 6, 2010Closed
Citation 1, item 1d
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Oct 6, 2010Closed
Citation 1, item 1e
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Oct 6, 2010Closed
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$900$540Oct 6, 2010Closed
Citation 2, item 1
29 CFR 1910.134(c)(3) · Respiratory protection
Other-than-serious$0$0Oct 6, 2010Closed
Citation 2, item 2
29 CFR 1910.134(g)(1)(ia) · Respiratory protection
Other-than-serious$0$0Oct 6, 2010Closed
Citation 2, item 3
29 CFR 1910.134(h)(1) · Respiratory protection
Other-than-serious$0$0Oct 6, 2010Closed

Inspection 314411711 OPENED JUN 25, 2010Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 28, 2010

210 Research Boulevard, Aberdeen, MD 21001 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,050$510Jul 29, 2010Closed
Citation 1, item 2
29 CFR 1926.403(i)(2)(ii) · Electrical equipment on job sites
Serious$1,050$510Jul 29, 2010Closed
Citation 2, item 1
29 CFR 50405 B01
Other-than-serious$0$0Jul 29, 2010Closed
Citation 2, item 2
29 CFR 50406 A01
Other-than-serious$0$0Jul 29, 2010Closed
Citation 2, item 3
29 CFR 50408 A01
Other-than-serious$0$0Jul 29, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(c)(3)

(3) The test operator shall direct the stream of irritant smoke from the smoke tube toward the faceseal area of the test subject, using the low flow pump or the squeeze bulb. The test operator shall begin at least 12 inches from the facepiece and move the smoke stream around the whole perimeter of the mask. The operator shall gradually make two more passes around the perimeter of the mask, moving to within six inches of the respirator.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.