OSHA SearchOSHA records by employer

Belfor Property Restoration: OSHA inspections and violations

Chester, Virginia · Residential Remodelers · NAICS 236118

1inspections
4citation items
$2,572current penalties
Jul 16, 2015last inspection

OSHA has inspected Belfor Property Restoration once in Virginia.

The inspection began on Jul 16, 2015 on a referral, in Chester.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $7,350 and now stand at $2,572, 65% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 2 items under 1910.213.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Belfor Property Restoration averages $2,572 (1 cited inspection).

Belfor Property Restoration: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Belfor Property Restoration and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340780238 OPENED JUL 16, 2015Closed

Referral · Partial · Safety · 22 employees at the site · Closed Oct 13, 2015

5000 Nairn Lane, Chester, VA 23831 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 16VAC25-60-120
Serious$3,675$2,572Sep 21, 2015Final
Citation 1, item 3b
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$3,675$0Sep 21, 2015Final
Citation 1, item 3c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Sep 21, 2015Final
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Sep 21, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(3)

(3) Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut.

29 CFR 1910.22 · General requirements

Other residential remodelers employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.