OSHA SearchOSHA records by employer

Bellefleur Masonry: OSHA inspections and violations

Lewiston, Maine · Masonry Contractors · NAICS 238140

4inspections
7citation items
$5,032current penalties
May 27, 2015last inspection

OSHA has inspected Bellefleur Masonry 4 times in Maine since 2004.

The latest one began on May 27, 2015 after a complaint, in Lisbon.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $7,125 and now stand at $5,032, 29% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Bellefleur Masonry averages $1,800 (1 cited inspection).

Bellefleur Masonry: OSHA citation items per year, 2004 to 2015
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Bellefleur Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340673755 OPENED MAY 27, 2015Closed

Complaint · Partial · Health · 25 employees at the site · Closed Sep 2, 2015

Lisbon High School, Lisbon, ME 04250 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$2,000$1,000Aug 13, 2015Final
Citation 1, item 1b
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$0$0Aug 13, 2015Final
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,600$800Aug 13, 2015Final

Inspection 112526223 OPENED DEC 16, 2009Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Jan 26, 2010

1 Robert Stevens Drive, York, ME 03909 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$750$750Jan 8, 2010Closed

Inspection 309984961 OPENED MAY 24, 2006Closed

Unprogrammed other · Partial · Safety · 7 employees at the site · Closed Jun 15, 2006

Sabattus & Stanley Streets, Lewiston, ME 04102 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,600$1,600Jun 5, 2006Closed

Inspection 307640557 OPENED APR 21, 2004Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jun 10, 2004

Sabattus & Stanley Streets, Lewiston, ME 04102 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$875$657May 26, 2004Closed
Citation 1, item 2
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$300$225May 26, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.503 · Fall protection training in construction

Other masonry contractors employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.