Bemus Point Village Hall: OSHA inspections and violations

Bemus Point, New York · Other General Government Support · NAICS 921190

1inspections
4citation items
$0current penalties
Feb 26, 2025last inspection

OSHA inspectors have visited Bemus Point Village Hall in New York one time.

It opened on Feb 26, 2025 as a planned inspection, in Bemus Point.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.37 (exit routes), 2 times.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Bemus Point Village Hall averages $0 across 1 cited inspection.

Bemus Point Village Hall: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

361employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Bemus Point Village Hall and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348065459 OPENED FEB 26, 2025Closed

Planned · Complete · Safety · Local government · 2 employees at the site · Closed Mar 11, 2025

13 Alburtus Avenue, Bemus Point, NY 14712 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(4) · Exit routes
Serious$0$0Mar 6, 2025Final
Citation 1, item 2
29 CFR 1910.37(b)(5) · Exit routes
Serious$0$0Mar 6, 2025Final
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Mar 6, 2025Final
Citation 2, item 1
29 CFR 12 NYCRR PART 801.29(A)
Other-than-serious$0$0Mar 6, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(a)(4)

(4) Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times.

29 CFR 1910.37(b)(5)

(5) Each doorway or passage along an exit access that could be mistaken for an exit must be marked “Not an Exit” or similar designation, or be identified by a sign indicating its actual use (e.g., closet).