OSHA SearchOSHA records by employer

Best Buy Co, Inc Store #128: OSHA inspections and violations

Reno, Nevada · Electronics Stores · NAICS 443142

1inspections
3citation items
$12,059current penalties
Mar 13, 2025last inspection

Best Buy Co, Inc Store #128 has one OSHA inspection on record in Nevada.

OSHA opened it on Mar 13, 2025 on a referral, in Reno.

From that inspection OSHA issued 3 citation items: 3 other-than-serious.

OSHA proposed $12,059 in penalties and the amount has not been reduced.

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Best Buy Co, Inc Store #128 averages $12,059 over 1 cited inspection in that time.

Best Buy Co, Inc Store #128: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

113employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Best Buy Co, Inc Store #128 and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348105677 OPENED MAR 13, 2025Closed

Referral · Partial · Safety · 15 employees at the site · Closed Jan 7, 2026

5575 South Virginia Street, Reno, NV 89502 · Electronics Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(b)(10) · Ladders in general industry
Other-than-serious$12,059$12,059Aug 29, 2025Final
Citation 2, item 1
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 29, 2025Final
Citation 2, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Aug 29, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.23(b)(10)

(10) Any ladder with structural or other defects is immediately tagged “Dangerous: Do Not Use” or with similar language in accordance with § 1910.145 and removed from service until repaired in accordance with § 1910.22(d), or replaced;

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other electronics stores employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.