OSHA SearchOSHA records by employer

Best Buy Stores, L.P, Store #493: OSHA inspections and violations

Alexandria, Virginia · Electronics Stores · NAICS 443142

1inspections
1citation items
$6,415current penalties
Feb 3, 2021last inspection

OSHA has inspected Best Buy Stores, L.P, Store #493 once in Virginia.

The inspection began on Feb 3, 2021 after a complaint, in Alexandria.

That inspection ended with 1 citation item: 1 serious.

Penalties were first proposed at $6,415 and still stand at $6,415.

How that compares: the median penalty per cited inspection for retail employers since 2015 is $1,750, and Best Buy Stores, L.P, Store #493 averages $6,415 (1 cited inspection).

Best Buy Stores, L.P, Store #493: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

256employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Best Buy Stores, L.P, Store #493 and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345133938 OPENED FEB 3, 2021Closed

Complaint · Partial · Safety · 80 employees at the site · Closed Jun 7, 2021

3401 Jefferson Davis Highway, Alexandria, VA 22305 · Electronics Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(e)(1) · Electrical wiring methods
Serious$6,415$6,415May 5, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(e)(1)

(e) Enclosures for damp or wet locations—(1) Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures. Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations.

Other electronics stores employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.