OSHA SearchOSHA records by employer

Best Plumbing & Electric LLC: OSHA inspections and violations

Honolulu, Hawaii · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
2citation items
$2,360current penalties
Feb 25, 2020last inspection

Since 2014, OSHA inspectors have visited Best Plumbing & Electric LLC in Hawaii 4 times.

The most recent inspection opened on Feb 25, 2020 as a planned inspection, in Honolulu.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $2,360 in total, stand where OSHA first set them.

The rule cited most here is 1910.253 (gas welding and cutting), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Best Plumbing & Electric LLC averages $2,360 across 1 cited inspection.

Best Plumbing & Electric LLC also files yearly injury logs with OSHA, summarized below.

Best Plumbing & Electric LLC: OSHA citation items per year, 2014 to 2020
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

67employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch Best Plumbing & Electric LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344704408 OPENED FEB 25, 2020Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 1, 2020

2224 Alahao Place Ste 203, Honolulu, HI 96819 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$2,360$2,360Jul 24, 2020Final
Citation 1, item 1b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Jul 24, 2020Final

Inspection 342303377 OPENED APR 26, 2017Closed

Planned · No inspection · Health · 20 employees at the site · Closed Apr 27, 2017

2224 Alahao Place Suite 203, Honolulu, HI 96819 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340658426 OPENED MAY 26, 2015Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jun 19, 2015

Building 9 Annex Building 9a, Pearl Harbor, HI 96860 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340066299 OPENED OCT 31, 2014Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Nov 19, 2014

1555 Wilder Ave, Honolulu, HI 96818 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Honolulu site logged 0 recordable injuries or illnesses among about 24 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Best Plumbing & Electric
Honolulu · 2022
24 000.01.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(ii)

(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

Other electrical contractors and other wiring installation contractors employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.