OSHA SearchOSHA records by employer

Betanco-Diaz Enterprise, LLC: OSHA inspections and violations

Fairfax, Virginia · Siding Contractors · NAICS 238170

1inspections
5citation items
$11,283current penalties
Jun 28, 2022last inspection

Betanco-Diaz Enterprise, LLC has one OSHA inspection on record in Virginia.

OSHA opened it on Jun 28, 2022 as a planned inspection, in Fairfax, and the case has not closed yet.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $16,119 in penalties. After settlements and reviews the total is $11,283, down 30%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Betanco-Diaz Enterprise, LLC averages $11,283 over 1 cited inspection in that time.

Betanco-Diaz Enterprise, LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Betanco-Diaz Enterprise, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346046634 OPENED JUN 28, 2022Open

Planned · Partial · Safety · 3 employees at the site · Open

4208 Marble Lane, Fairfax, VA 22033 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR ?59.1-408.1
Serious$13,434$9,404Sep 12, 2022Final
Citation 1, item 1b
29 CFR 59.1-410.A
Serious$0$0Sep 12, 2022Final
Citation 1, item 2a
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$2,685$1,880Sep 12, 2022Final
Citation 1, item 2b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Sep 12, 2022Final
Citation 1, item 2c
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Sep 12, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.