OSHA SearchOSHA records by employer

Bethlehem TN DPW: OSHA inspections and violations

Delmar, New York · Water Supply and Irrigation Systems · NAICS 221310

6inspections
14citation items
$0current penalties
Sep 16, 2019last inspection

Since 1991, OSHA inspectors have visited Bethlehem TN DPW in New York 6 times.

The most recent inspection opened on Sep 16, 2019 to follow up on an earlier case, in Delmar.

In all, OSHA issued 14 citation items: 10 serious and 4 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1926.651 (excavations), 3 times.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Bethlehem TN DPW averages $0 across 1 cited inspection.

Bethlehem TN DPW: OSHA citation items per year, 1991 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Bethlehem TN DPW and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344309521 OPENED SEP 16, 2019Closed

Follow-up · Partial · Safety · Local government · 19 employees at the site · Closed Oct 4, 2019

308 Kenwood Ave., Delmar, NY 12054 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343877684 OPENED MAR 26, 2019Closed

Referral · Partial · Safety · Local government · 19 employees at the site · Closed Oct 4, 2019

308 Kenwood Ave., Delmar, NY 12054 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(e) · Excavations
Serious$0$0Jul 31, 2019Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Jul 31, 2019Final
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jul 31, 2019Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jul 31, 2019Final
Citation 2, item 1
29 CFR 12 NYCRR PART 801.40(A)
Other-than-serious$0$0Jul 31, 2019Final

Inspection 313865271 OPENED NOV 18, 2010Closed

Referral · Partial · Safety · Local government · 4 employees at the site · Closed Dec 13, 2010

698 Kenwood Ave., Delmar, NY 12054 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305440430 OPENED AUG 7, 2003Closed

Follow-up · Partial · Health · Local government · 25 employees at the site · Closed Aug 13, 2003

308 Kenwood Ave, Delmar, NY 12054 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305438152 OPENED MAR 11, 2003Closed

Referral · Partial · Health · Local government · 25 employees at the site · Closed Aug 13, 2003

308 Kenwood Ave, Delmar, NY 12054 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$0$0Apr 22, 2003Closed
Citation 1, item 2
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$0$0Apr 22, 2003Closed
Citation 1, item 3
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$0$0Apr 22, 2003Closed
Citation 1, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$0$0Apr 22, 2003Closed
Citation 1, item 5
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Apr 22, 2003Closed
Citation 1, item 6
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Apr 22, 2003Closed
Citation 2, item 1
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Apr 22, 2003Closed
Citation 2, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Apr 22, 2003Closed
Citation 2, item 3
29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens
Other-than-serious$0$0Apr 22, 2003Closed

Inspection 115923617 OPENED FEB 19, 1991Closed

Referral · Partial · Safety · Local government · 5 employees at the site · Closed Feb 19, 1991

Feura Bush Road & Rte 9w, Glenmont, NY 12077 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(i)

(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(1)

(c) General requirements. (1) The employer shall evaluate the workplace to determine if any spaces are permit- required confined spaces.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water supply and irrigation systems employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.