Inspection 343492849 OPENED SEP 26, 2018Closed
509 44th Street, Union City, NJ 07087 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Union City, New Jersey · Masonry Contractors · NAICS 238140
BHD Builders LLC has 2 OSHA inspections on record in New Jersey, the first in 2018.
OSHA's last visit started on Sep 26, 2018 to follow up on an earlier case, in Union City.
Across those inspections OSHA issued 8 citation items: 8 serious.
OSHA proposed $26,606 in penalties. After settlements and reviews the total is $13,303, down 50%.
Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. BHD Builders LLC averages $13,303 over 1 cited inspection in that time.
New Jersey · latest 90 days of OSHA records
270employers cited
10 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch BHD Builders LLC and get notified the morning OSHA posts a new citation for it.
Watch this company509 44th Street, Union City, NJ 07087 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
509 44th Street, Union City, NJ 07087 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.100(a) · Hard hats in construction |
Serious | $3,326 | $1,663 | Jul 12, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.451(h)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Jul 12, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.451(c)(3) · Scaffolds, general requirements |
Serious | $3,880 | $1,940 | Jul 12, 2018 | Final |
| Citation 1, item 3 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $3,880 | $1,940 | Jul 12, 2018 | Final |
| Citation 1, item 4 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $3,880 | $1,940 | Jul 12, 2018 | Final |
| Citation 1, item 5 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $3,880 | $1,940 | Jul 12, 2018 | Final |
| Citation 1, item 6 29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements |
Serious | $3,880 | $1,940 | Jul 12, 2018 | Final |
| Citation 1, item 7 29 CFR 1926.454(a) · Scaffold training |
Serious | $3,880 | $1,940 | Jul 12, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.100(a)
(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.
29 CFR 1926.451(c)(3)
(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.