OSHA SearchOSHA records by employer

Big D Concrete, Inc.: OSHA inspections and violations

Dallas, Texas · Ready-Mix Concrete Manufacturing · NAICS 327320

5inspections
16citation items
$47,725current penalties
Oct 21, 2021last inspection

OSHA has inspected Big D Concrete, Inc. 5 times in Texas since 2017.

The latest one began on Oct 21, 2021 to follow up on an earlier case, in Dallas.

Those inspections ended with 16 citation items: 9 serious, 1 repeat and 6 other-than-serious.

Penalties were first proposed at $88,038 and now stand at $47,725, 46% lower after settlements or reviews.

Noise comes up most often in these citations: 3 items under 1910.95.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Big D Concrete, Inc. averages $9,545 (5 cited inspections).

Big D Concrete, Inc. also files yearly injury logs with OSHA, summarized below.

The Wage and Hour Division has 2 cases on it since 2015, with $25,398 in back wages owed to workers.

Big D Concrete, Inc.: OSHA citation items per year, 2017 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Big D Concrete, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345593636 OPENED OCT 21, 2021Closed

Follow-up · Partial · Safety · 30 employees at the site · Closed Dec 20, 2022

10361 Bickham Road, Dallas, TX 75220 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$7,510$4,506Nov 22, 2021Final
Citation 1, item 1b
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$0$0Nov 22, 2021Final
Citation 2, item 1
29 CFR 1910.243(b)(2) · Guarding of portable powered tools
Repeat$18,023$10,814Nov 22, 2021Final

Inspection 344465596 OPENED NOV 21, 2019Closed

Complaint · Partial · Safety · 76 employees at the site · Closed Aug 28, 2020

10361 Bickham Road, Dallas, TX 75220 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.29(b)(2) · Fall protection systems in general industry
Serious$8,906$5,344Feb 26, 2020Final
Citation 1, item 2
29 CFR 1910.243(b)(2) · Guarding of portable powered tools
Serious$5,937$3,562Feb 26, 2020Final
Citation 2, item 1a Other-than-serious$833$500Feb 26, 2020Final
Citation 2, item 1b Other-than-serious$0$0Feb 26, 2020Final
Citation 2, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$833$500Feb 26, 2020Final

Inspection 344170584 OPENED JUL 22, 2019Closed

Planned · Partial · Health · 90 employees at the site · Closed Aug 30, 2019

10361 Bickham Rd, Dallas, TX 75220 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 2, 2019Final
Citation 1, item 2 Other-than-serious$0$0Aug 2, 2019Final

Inspection 342725546 OPENED OCT 24, 2017Closed

Complaint · Partial · Health · 50 employees at the site · Closed Aug 31, 2018

10361 Bickham Rd, Dallas, TX 75220 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$9,054$4,500Jan 24, 2018Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$9,054$4,500Jan 24, 2018Final
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$9,054$4,500Jan 24, 2018Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$726$0Jan 24, 2018Final

Inspection 342725801 OPENED OCT 24, 2017Closed

Complaint · Partial · Safety · 50 employees at the site · Closed Aug 13, 2018

10361 Bickham Road, Dallas, TX 75220 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$9,054$4,500Jan 24, 2018Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$9,054$4,500Jan 24, 2018Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Dallas site logged 7 recordable injuries or illnesses among about 91 workers: 9.0 per 100 full-time workers, against a median of 3.4 for its industry. Those cases cost 407 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Big D Concrete, Inc.
Dallas · 2024
91 739.03.4
Construction Materials
Dallas · 2017
55 3313.63.4

Included with any plan: 1 more yearly log from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Jan 23, 2018 to Feb 15, 2020
Dallas
9594$25,398$0
Oct 5, 2013 to Oct 28, 2015
Dallas
600$0$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.141 · Sanitation

29 CFR 1910.141(d)(2)(iii)

(iii) Hand soap or similar cleansing agents shall be provided.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other ready-mix concrete manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.