OSHA SearchOSHA records by employer

Big Lake Gas Plant, LP: OSHA inspections and violations

Big Lake, Texas · Oil and Gas Extraction · NAICS 211112

2inspections
10citation items
$37,056current penalties
Jul 26, 2018last inspection

Since 2018, OSHA inspectors have visited Big Lake Gas Plant, LP in Texas 2 times.

The most recent inspection opened on Jul 26, 2018 as a planned inspection, in Big Lake.

In all, OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

The proposed penalties came to $42,670; today they stand at $37,056, 13% less.

The rule cited most here is 1910.119 (process safety management), 5 times.

Among mining and oil and gas employers, the typical cited inspection since 2015 ends with a $2,883 penalty. Big Lake Gas Plant, LP averages $18,528 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Big Lake Gas Plant, LP: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

405employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Big Lake Gas Plant, LP and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343334702 OPENED JUL 26, 2018Closed

Planned · Complete · Health · 16 employees at the site · Closed Oct 22, 2019

189 Gas Plant Road, Big Lake, TX 76932 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.119(e)(3)(v) · Process safety management
Serious$5,304$5,304Jan 24, 2019Final
Citation 1, item 2
29 CFR 1910.119(e)(6) · Process safety management
Serious$5,304$5,304Jan 24, 2019Final
Citation 1, item 3a
29 CFR 1910.119(f)(3) · Process safety management
Serious$3,031$3,035Jan 24, 2019Final
Citation 1, item 3b
29 CFR 1910.119(g)(1)(i) · Process safety management
Serious$3,031$0Jan 24, 2019Final
Citation 1, item 5
29 CFR 1910.119(j)(2) · Process safety management
Other-than-serious$5,304$5,304Jan 24, 2019Final

Inspection 343093357 OPENED APR 15, 2018Closed

Fatality or catastrophe · Partial · Health · 16 employees at the site · Closed Aug 9, 2019

189 Gas Plant Road, Big Lake, TX 76932 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps

Incident on Apr 14, 2018 (fatal): Employee is overcome by hydrogen sulfide fumes and is killed

At 11:30 p.m. on April 14, 2018, an employee was performing maintenance on the acid cat and replaced the injection methanol pump. The employee was overcome by a high concentration of hydrogen sulfide and was asphyxiated.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 1910.120(q)(3)(iv) · Hazardous waste operations and emergency response
Serious$5,174$10,348Oct 2, 2018Final
Citation 1, item 3b
29 CFR 1910.134(d)(2)(i)(b) · Respiratory protection
Serious$5,174$0Oct 2, 2018Final
Citation 1, item 4
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$5,174$5,174Oct 2, 2018Final
Citation 1, item 5a
29 CFR 1910.1000(b)(2) · Air contaminants
Serious$5,174$2,587Oct 2, 2018Final
Citation 1, item 5b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Oct 2, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(2)

(2) Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under “acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift.”

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.119 · Process safety management

29 CFR 1910.119(e)(3)(v)

(v) Facility siting;

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

Other oil and gas extraction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.