OSHA SearchOSHA records by employer

Big Stack Masonry Inc.: OSHA inspections and violations

Holladay Cottonwood, Utah · Masonry Contractors · NAICS 238140

2inspections
6citation items
$4,050current penalties
Dec 7, 2015last inspection

Big Stack Masonry Inc. has 2 OSHA inspections on record in Utah, the first in 2015.

OSHA's last visit started on Dec 7, 2015 on a referral, in Salt Lake City, and the case has not closed yet.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $4,050 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Big Stack Masonry Inc. averages $2,025 over 2 cited inspections in that time.

Big Stack Masonry Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Big Stack Masonry Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341102994 OPENED DEC 7, 2015Open

Referral · Partial · Safety · 4 employees at the site · Open

993 Bending River Road, Salt Lake City, UT 84104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,050$1,050Dec 17, 2015Final
Citation 1, item 1b
29 CFR 1926.454(c)(3) · Scaffold training
Serious$0$0Dec 17, 2015Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$1,500Dec 17, 2015Final

Inspection 340949742 OPENED SEP 28, 2015Closed

Referral · Partial · Safety · 4 employees at the site · Closed Feb 1, 2024

4644 South Holliday Blvd, Holladay Cottonwood, UT 84121 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$1,500Nov 25, 2015Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Nov 25, 2015Final
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Nov 25, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Utah

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.